UVOZ-3300C ozone concentration analyzer
The principle: dual beam UV photometer absorption method, used to detect the outlet ozone concentration of generator or tail gas.
The range: 0-300g/Nm3, 0-200g/Nm3
The features:This analyzer can continuously running and automatic zeroing to ensure the stability of the detection.
The brand:
1. Product description
Based on Lambert Bill's law, the analyzer of UVOZ-3300C by measuring the change of the intensity of the light signal before and after the UV absorption of the ozone to calculate the current ozone concentration.
The equipment adopts the advanced dual UV light source system with the intelligent management system of the lamp tube, which can make the UV lamp tube reach the measuring state quickly after the machine is opened. Using the separating photocell technology enables the analyzer has the characteristics of no leakage, anti high pressure, anti large-flow sampling gas impact, easy cleaning, convenient maintenance, simple operation and low cost. This instrument is mainly used for continuous detection of ozone gas in various industrial environments, and can also be used to detect ozone gas in pipelines and containers. It is widely used in pharmaceutical, chemical, municipal, sewage treatment and other industries. It measures the ozone generator outlet concentration and the production of ozone generator.
The ozone analyzer has a touch screen operation interface, which shows the real-time ozone concentration. And the touch screen is also with the pressure & temperature compensation display. For the high concentration (g/Nm3) range, it has the function of flow input, which can display the output of the ozone generator in real time. With two sets of relay signal output, users can choose high alarm point and low alarm point signal output connection. The core component adopts long-life uv light system & the high light transmittance quartz to ensure the stability of the zero point and prevent zero drifting from affecting the detection accuracy. According to the optical cuvette technology abroad, we design a pressure resistant & shock resistant seperated cuvette structure. The gas flow, pressure and flow rate remain unchanged at the time of zeroing to prevent the impact of airflow shock. There is no need to close ozone inputing at zeroing to ensure that the equipment can run continuously for 24 hours a day.
Application areas: ozone generator manufacturers, municipal water industry, industrial sewage industry, fine chemical industry food and drinking water industry, space disinfection industry, swimming pool disinfection industry, essence synthesis industry and other use of ozone generator industry.
UVOZ-3300C ozone analyzer, optional range and working mode.
Range | Sampling method | Application areas |
0-300g/Nm3 | Active pressure sampling, with pressure, temperature compensation | Real-time detection of ozone generator outlet concentration |
0-100g/Nm3 | Active pressure sampling, with pressure, temperature compensation | Real-time detection of ozone generator outlet concentration |
0-50g/Nm3 | Active pressure sampling, or pumping sampling, with pressure, temperature compensation | Ozone generator outlet or ozone concentration detection of tail gas. |
0-1000ppm | Active pressure sampling, or pumping sampling, with pressure, temperature compensation | Real-time detection of ozone concentration in box. |
0-100ppm | Active pressure sampling, or pumping sampling, with pressure, temperature compensation | Real-time detection of space or ozone concentration in room. |
2.Technical parameter
Model : UVOZ-3300C
Detection range:0-300g/Nm3
Optional range:0-200g/Nm3,0-100 g/Nm3, 0-50g/Nm3,0-1000ppm,0-100ppm;
Light source life:about 700 hours
Sampling method: active pressure sampling,pumping sampling(optional);
Display interface: 4.3 inch touch screen operation interface
Content interface: ozone concentration, temperture, pressure
Auxiliary function: temperature compensation and pressure compensation
Display unit:g/Nm3,mg/NL,%WT,ppm ,mg/Nm3 (optional)
Display resolution: 0.01 g/m3,0.01ppm
Gas flow:0.5L±0.2L/min;
Input pressure:<0.1MPa;
Concentration error : max 0.5%;
Line deviation : max 0.2%;
Zero drifting:<±0.3%.FS(whole range);
Response time : signal 0.03s, display 0.3s;
Ambient temperature : -20~50ºC;
Pipeline connection mode:quick wring (stainless steel);
Sampling caliber of series connection:Φ8(8mm*6mm)(optional);
Sampling caliber of bypass connection:Φ6(6mm*4mm);
Communication mode:RS-485;
Output mode:4-20mA;
Relay signal: high alarm point relay signal, low alarm point relay signal.
Power supply:AC 110-220V;
Dimension:160mm(height)×260mm(width)×300mm(depth);
Free warranty: 24 months (main engine);
Note: standard configuration (built-in): flowmeter, ozone exhaust gas catalytic converter, air inputting filter.
(Remark:1mg/L=1g/m3=467PPM);
3.Product features
Detection method:dual beam UV photometer absorption method,long life light source system, high measuring accuracy.
Principle:according to Lambert Bill law, measure precisely by photometric absorption principle.
Light source system:imported long life uv light source system (wavelength 253.7nm), free warranty for 3 years.
Using method:indoor installation and use, configure power and signal terminals.
Cuvette system:separated optical cuvette with no leakage and anti high-pressure, high-flow rate, pmpact of sampling gas.
Intelligent compensation:built in temperature and pressure compensation and display, with automatic compensation function of light source.
Operation method:the user can select manual zeroing mode or automatic zeroing calibration according to the running state, and can set up automatic zeroing time.
Display unit:g/Nm3,mg/NL,%WT,ppm ,mg/Nm3(optical)
Display data:high definition color touch screen, setting the into-gas mass flow about high concentration range, real-time display the generator production.
Output function:4-20mA,RS485 communication,two sets of alarm point output, electronic flowmeter input, etc.
Standard configuration:anticorrosive flowmeter, ozone tail gas destroyer, gas in-putting filter.
4.product structure
Signal terminal output
(01)4-20MA+ Current signal output | (08)ALARM LOW : NO |
(02)4-20MA- Current signal output | (09)ALARM LOW: COM |
(03)RS485+ communication interface | (10)ALARM LOW: NC |
(04)RS485- communication interface | (11)+ FLOW SIGNAL+ production calculation flow signal access |
(05)ALARM HIGH: NO | (12)- FLOW SIGNAL- production calculation flow signal access |
(06)ALARM HIGH: COM | (13)+FUNCTION+Reservation function: ozone generator allocation |
(07)ALARM HIGH: NC | (14)-FUNCTION-Reservation function: ozone generator allocation |