Basic Info.
Specification
160mm*260mm*300mm
Product Description
1.Company Introduction
Shandong ZHISO Environmental Tech Co., Ltd. is a joint company specialized in design & develop & selling of the instrument of environmental protection. ZHISO company is a professional R & D and sales company, mainly engaged in the UV detection method of ozone gas concentration principle and development of UV & infrared light absorption detection. We have our own manufacturer : Zibo Zhiprer Automation Technology Co., Ltd that mainly engaged in the production of UV ozone detector/ ozone gas analyzer.ZHISO company has it's own brand " ZHISO" and the main products are about:Ozone analyzer / Water quality / Toxic and harmful gas detector / Ozone generator. ZHISO company rely on the advantages & experience of high-level technical talents, to focuse on new products development. We are willing to cooperate with high-tech companies to work together for ozone application industry.
2.Product Introduction
UVOZ-3300C ozone concentration analyzer
The principle: dual beam UV photometer absorption method, used to detect the outlet ozone concentration of generator or tail gas.
The range: 0-300g/Nm3, 0-200g/Nm3
The features:This analyzer can continuously running and automatic zeroing to ensure the stability of the detection.
The brand:
A. General description
Based on Lambert Bill's law, the analyzer of UVOZ-3300C by measuring the change of the intensity of the light signal before and after the UV absorption of the ozone to calculate the current ozone concentration.
The ozone analyzer has a touch screen operation interface, which shows the real-time ozone concentration. And the touch screen is also with the pressure & temperature compensation display. For the high concentration (g/Nm3) range, it has the function of flow input, which can display the output of the ozone generator in real time.
Application areas: ozone generator manufacturers, municipal water industry, industrial sewage industry, fine chemical industry food and drinking water industry, space disinfection industry, swimming pool disinfection industry, essence synthesis industry and other use of ozone generator industry.
UVOZ-3300C ozone analyzer, optional range and working mode.
Range | Sampling method | Application areas |
0-300g/Nm3 | Active pressure sampling, with pressure, temperature compensation | Real-time detection of ozone generator outlet concentration |
0-100g/Nm3 | Active pressure sampling, with pressure, temperature compensation | Real-time detection of ozone generator outlet concentration |
0-50g/Nm3 | Active pressure sampling, or pumping sampling, with pressure, temperature compensation | Ozone generator outlet or ozone concentration detection of tail gas. |
0-1000ppm | Active pressure sampling, or pumping sampling, with pressure, temperature compensation | Real-time detection of ozone concentration in box. |
0-100ppm | Active pressure sampling, or pumping sampling, with pressure, temperature compensation | Real-time detection of space or ozone concentration in room. |
B.Technical parameter
Model : UVOZ-3300C
Detection range:0-300g/Nm3
Optional range:0-200g/Nm3,0-100 g/Nm3, 0-50g/Nm3,0-1000ppm,0-100ppm;
Light source life:about 700 hours
Sampling method: active pressure sampling,pumping sampling(optional);
Display interface: 4.3 inch touch screen operation interface
Content interface: ozone concentration, temperture, pressure
Auxiliary function: temperature compensation and pressure compensation
Display unit:g/Nm3,mg/NL,%WT,ppm ,mg/Nm3 (optional)
Display resolution: 0.01 g/m3,0.01ppm
Gas flow:0.5L±0.2L/min;
Input pressure:<0.1MPa;
Concentration error : max 0.5%;
Line deviation : max 0.2%;
Zero drifting:<±0.3%.FS(whole range);
Response time : signal 0.03s, display 0.3s;
Ambient temperature : -20~50ºC;
Pipeline connection mode:quick wring (stainless steel);
Sampling caliber of series connection:Φ8(8mm*6mm)(optional);
Sampling caliber of bypass connection:Φ6(6mm*4mm);
Communication mode:RS-485;
Output mode:4-20mA;
Relay signal: high alarm point relay signal, low alarm point relay signal.
Power supply:AC 110-220V;
Dimension:160mm(height)×260mm(width)×300mm(depth);
Free warranty: 24 months (main engine);
Note: standard configuration (built-in): flowmeter, ozone exhaust gas catalytic converter, air inputting filter.
(Remark:1mg/L=1g/m3=467PPM);
C.Product features
Detection method:dual beam UV photometer absorption method,long life light source system, high measuring accuracy.
Principle:according to Lambert Bill law, measure precisely by photometric absorption principle.
Light source system:imported long life uv light source system (wavelength 253.7nm), free warranty for 3 years.
Using method:indoor installation and use, configure power and signal terminals.
Cuvette system:separated optical cuvette with no leakage and anti high-pressure, high-flow rate, pmpact of sampling gas.
Intelligent compensation:built in temperature and pressure compensation and display, with automatic compensation function of light source.
Operation method:the user can select manual zeroing mode or automatic zeroing calibration according to the running state, and can set up automatic zeroing time.
Display unit:g/Nm3,mg/NL,%WT,ppm ,mg/Nm3(optical)
Display data:high definition color touch screen, setting the into-gas mass flow about high concentration range, real-time display the generator production.
Output function:4-20mA,RS485 communication,two sets of alarm point output, electronic flowmeter input, etc.
Standard configuration:anticorrosive flowmeter, ozone tail gas destroyer, gas in-putting filter.
D. Product structure
Signal terminal output
(01)4-20MA+ Current signal output | (08)ALARM LOW : NO |
(02)4-20MA- Current signal output | (09)ALARM LOW: COM |
(03)RS485+ communication interface | (10)ALARM LOW: NC |
(04)RS485- communication interface | (11)+ FLOW SIGNAL+ production calculation flow signal access |
(05)ALARM HIGH: NO | (12)- FLOW SIGNAL- production calculation flow signal access |
(06)ALARM HIGH: COM | (13)+FUNCTION+Reservation function: ozone generator allocation |
(07)ALARM HIGH: NC | (14)-FUNCTION-Reservation function: ozone generator allocation |
3. Issues of concern
A. Payment Terms:
1.T/T , PAYPAL, WU, 100% prepaid.
2. lead time 3-5days after payment
B. Our Service:
1. All products and accessories have been 100% tested before shipping.
2. We provide 12 months waranty on the host for non-deliberate damage
C. F&Q:
Q1. Can i have a sample oeder
A1: The sample oeder to test are welcomed at the first time.
Q2:How about your production capacity and quality control?
A2: We have written instructions for incoming & inline & final inspection and testing All the qualified products must be pass the 100% audit by QE staff. And the failed products will be clearly marked and seperated to repair and re-inspect.
Q3: How can i get a good price?
A3: We are 100% sure that we can provide you the most competitive price with high values.Pls trus t us and attache your detail request, oeder quantity, delivery mode, payment terms.